Water supply pressure reducing valve - List of Manufacturers, Suppliers, Companies and Products

Water supply pressure reducing valve Product List

1~2 item / All 2 items

Displayed results

Residential Water Supply Pressure Reducing Valve "Benkei Series RD-44SN Type"

A pressure-reducing valve with a shut-off valve for individual water supply that operates reliably from low differential pressure to high differential pressure.

The "Benkei Series RD-44SN Type" is a pressure reducing valve with a shut-off valve for individual water supply, installed within the pipe shafts of hotels and apartment buildings. It is designed to stabilize fluctuations in water supply pressure caused by differences in elevation in mid- to high-rise buildings. Thanks to the test gag method, water pressure testing can be conducted even after installation of the pressure reducing valve. Additionally, the shut-off valve is separable, which enhances workability and makes it easy to replace the pressure reducing valve or maintain water supply equipment after piping. 【Specifications】 ■ Nominal diameter: 20 ■ Applicable fluid: Tap water, hot water ■ Fluid temperature: 5–90℃ (when using pipe end core: 5–40℃) ■ Applicable pressure on the primary side: 1.0MPa or less ■ Set pressure (adjustable pressure range) ・ RD-44SN Type L: 0.08MPa (0.05–0.12MPa) ・ RD-44SN Type M: 0.2MPa (0.11–0.23MPa) ・ RD-44SN Type H: 0.25MPa (0.2–0.3MPa) *For more details, please download the PDF or feel free to contact us.

  • Piping and insulation

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Residential Water Supply Pressure Reducing Valve "Benkei Series"

Pressure reducing valves and stop valves can be directly connected! This further reduces construction work and saves space in piping.

The "Benkei Series" is a pressure-reducing valve installed for individual water supply to stabilize fluctuations in water pressure due to height differences in mid-rise and high-rise buildings. Even after installation, water pressure testing can be conducted with the pressure-reducing valve in place. Additionally, replacing the pressure-reducing valve or maintaining water supply fixtures after piping is also made easy. Furthermore, maintenance of the disc and vent is simple, and pressure adjustment after assembly is no longer necessary. 【Features】 ■ Supplies soft water ■ Compact ■ Lightweight ■ Test gag method and cassette method ■ Primary side stop valve fittings are also available *For more details, please refer to the PDF document or feel free to contact us.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration